Quick Reference Guide

174 Storage Management Message Reference
2309 A physical
disk is incom-
patible.
Warning /
Non-critical
Cause: You have attempted
to replace a disk with
another disk that is using an
incompatible technology.
For example, you may have
replaced one side of a
mirror with a SAS disk
when the other side of
the mirror is using SATA
technology.
Action: See the hardware
documentation for
information on replacing
disks.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2310 A virtual
disk is
permanently
degraded.
Critical /
Failure / Error
Cause: A redundant virtual
disk has lost redundancy.
This may occur when the
virtual disk suffers the
failure of multiple physical
disks. In this case, both the
source physical disk and
the target disk with
redundant data have failed.
A rebuild is not possible
because there is no
redundancy.
Action: Replace the failed
disks and restore from
backup.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information