2306 Bad block
table is
80% full.
Warning /
Non-critical
Cause: The bad block table
is used for remapping bad
disk blocks. This table fills,
as bad disk blocks are
remapped. When the table
is full, bad disk blocks can
no longer be remapped, and
disk errors can no longer be
corrected. At this point,
data loss can occur. The bad
block table is now 80% full.
Action: Back up your data.
Replace the disk generating
this alert and restore from
back up.
Clear Alert
Number:
None.
Related Alert
Number:
2307
2307 Bad block
table is full.
Unable to log
block %1
Critical /
Failure / Error
Cause: The bad block table
is used for remapping bad
disk blocks. This table fills,
as bad disk blocks are
remapped. When the table
is full, bad disk blocks can
no longer be remapped and
disk errors can no longer be
corrected. At this point,
data loss can occur. The %1
indicates a substitution
variable. The text for this
substitution variable is
displayed with the alert in
the Alert Log and can vary
depending on the
situation.
Action: Replace the disk
generating this alert. If
necessary, restore your data
from backup.
Clear Alert
Number:
None.
Related Alert
Number:
2048