Quick Reference Guide
170 Storage Management Message Reference
2300 The enclosure
is unstable.
Critical /
Failure / Error
Cause: The controller is
not receiving a consistent
response from the
enclosure. There could be
a firmware problem or an
invalid cabling
configuration. If the cables
are too long, they will
degrade the signal.
Action: Power down all
enclosures attached to the
system and reboot the
system. If the problem
persists, upgrade the
firmware to the latest
supported version. You can
download the most current
version of the driver and
firmware from
support.dell.com.
Make sure the cable
configuration is valid.
See the hardware
documentation for valid
cabling configurations.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2301 The enclosure
has a
hardware
error.
Critical /
Failure / Error
Cause: The enclosure or an
enclosure component is in
a Failed or Degraded state.
Action: Check the health
of the enclosure and its
components. Replace any
hardware that is in a Failed
state. See the hardware
documentation for more
information.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information