Quick Reference Guide
Storage Management Message Reference 167
2290 Single-bit
ECC error.
Warning /
Non-critical
Cause: An error involving a
single bit has been
encountered during a read
or write operation. The
error correction algorithm
has corrected this error.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
2291 An EMM has
been
discovered.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
2292 Comm-
unication
with the
enclosure has
been lost.
Critical /
Failure / Error
Cause: The controller has
lost communication with an
EMM. The cables may be
loose or defective.
Action: Make sure the
cables are attached
securely. Reboot the
system.
Clear Alert
Number:
2162.
Related Alert
Number:
None.
2293 The EMM
has failed.
Critical /
Failure / Error
Cause: The failure may be
caused by a loss of power to
the EMM. The EMM self
test may also have
identified a failure.
There could also be a
firmware problem or a
multi-bit error.
Action: Replace the EMM.
See the hardware
documentation for
information on replacing
the EMM.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information