164 Storage Management Message Reference
2282 Hot spare
SMART
polling failed.
Critical /
Failure / Error
Cause: The controller
firmware attempted a
SMART polling on the hot
spare but was unable to
complete it. The controller
has lost communication
with the hot spare.
Action: Check the health
of the disk assigned as a
hot spare. You may need to
replace the disk and
reassign the hot spare.
Make sure the cables are
attached securely. See the
Cables Attached Correctly
section in the
Dell OpenManage Server
Administrator Storage
Management User’s Guide
for more information on
checking the cables.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2285 A disk media
error was
corrected
during
recovery.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information