Quick Reference Guide
144 Storage Management Message Reference
2210 Battery
requires
recondition-
ing. Initiate
the battery
learn cycle.
Warning /
Non-critical
Cause: Battery requires
reconditioning.
Action: Initiate the battery
learn cycle.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2211 The physical
disk is not
supported.
Warning /
Non-critical
Cause: The physical disk
may not have a supported
version of the firmware or
the disk may not be
supported by Dell.
Action: If the disk is
supported by Dell,
update the firmware to a
supported version. If the
disk is not supported by
Dell, replace the disk with
one that is supported.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2212 The
controller
battery temp-
erature is
above normal.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
2213 Recharge
count
maximum
exceeded
Warning /
Non-critical
Cause: The battery has
been recharged more times
than the battery recharge
limit allows.
Action: Replace the
battery pack.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert