Quick Reference Guide

Storage Management Message Reference 143
2206 The only hot
spare
available is a
SATA disk.
SATA disks
cannot
replace
SAS disks.
Warning /
Non-critical
Cause: The only physical
disk available to be assigned
as a hot spare is using
SATA technology.
The physical disks in the
virtual disk are using SAS
technology. Because of this
difference in technology,
the hot spare cannot
rebuild data if one of the
physical disks in the virtual
disk fails.
Action: Add a SAS disk
that is large enough to be
used as the hot spare and
assign the new disk as a hot
spare.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2207 The only hot
spare available
is a SAS disk.
SAS disks
cannot
replace SATA
disks.
Warning /
Non-critical
Cause: The only physical
disk available to be
assigned as a hot spare is
using SAS technology.
The physical disks in the
virtual disk are using SATA
technology. Because of this
difference in technology,
the hot spare cannot
rebuild data if one of the
physical disks in the virtual
disk fails.
Action: Add a SATA disk
that is large enough to be
used as the hot spare and
assign the new disk as a hot
spare.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert