Quick Reference Guide

142 Storage Management Message Reference
2203 A dedicated
hot spare
failed.
Warning /
Non-critical
Cause: The controller is
unable to communicate
with a disk that is assigned
as a dedicated hot spare.
The disk may have failed or
been removed. There may
also be a bad or loose cable.
Action: Check if the disk is
healthy and that it has not
been removed. Check the
cables. If necessary, replace
the disk and reassign the
hot spare.
Clear Alert
Number:
None.
Related Alert
Number:
2048
2204 A dedicated
hot spare has
been
removed.
OK / Normal /
Informational
Cause: The controller is
unable to communicate
with a disk that is assigned
as a dedicated hot spare.
The disk may have been
removed. There may also
be a bad or loose cable.
Action: Check if the disk is
healthy and that it has not
been removed. Check the
cables. If necessary,
replace the disk and
reassign the hot spare.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2205 A dedicated
hot spare has
been auto-
matically
unassigned.
OK / Normal /
Informational
Cause: The hot spare is no
longer required because the
virtual disk it was assigned
to has been deleted.
Action: None.
Clear Alert
Number:
None.
Related Alert
Number:
2098, 2161,
2196
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information