Quick Reference Guide

138 Storage Management Message Reference
2191 Multiple
enclosures are
attached to
the controller.
This is an
unsupported
config-
uration.
Critical /
Failure / Error
Cause: There are too many
enclosures are attached to
the controller port. When
the enclosure limit is
exceeded, the controller
loses contact with all
enclosures attached to
the port.
Action: Remove the last
enclosure. You must
remove the enclosure that
has been added last and is
causing the enclosure limit
to exceed.
Clear Alert
Number:
None.
Related Alert
Number:
2211
2192 The virtual
disk Check
Consistency
has made
corrections
and
completed.
OK / Normal /
Informational
Cause: The virtual disk
Check Consistency has
identified errors and made
corrections. For example,
the Check Consistency
may have encountered a
bad disk block and
remapped the disk block to
restore data consistency.
This alert is for
informational purposes.
Action: This alert is for
informational purposes
only and no additional
action is required. As a
precaution, monitor the
Alert Log for other errors
related to this virtual disk.
If problems persist, contact
Dell Technical Support.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information