136 Storage Management Message Reference
2184 Replace
member
operation
cancelled on
physical disk
OK / Normal /
Informational
Cause: User cancelled the
replace member operation.
Action: None
Clear Alert
Number:
None
Related Alert
Number:
2060
2185 Replace
member
operation
stopped for
rebuild of hot
spare on
physical disk
Wa rn i ng /
Non-critical
Cause: This alert is
provided for informational
purposes
Action: None
Clear Alert
Number:
None
Related Alert
Number:
2060
2186 The
controller
cache has
been
discarded.
Warning /
Non-critical
Cause: The controller has
flushed the cache and any
data in the cache has been
lost. This may happen if
the system has memory or
battery problems that
cause the controller to
distrust the cache. Although
user data may have been
lost, this alert does not
always indicate that relevant
or user data has been lost.
Action: Verify that the
battery and memory are
functioning properly.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2187 Single-bit
ECC error
limit
exceeded.
Warning /
Non-critical
Cause: The system
memory is malfunctioning.
Action: Replace the
battery pack.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information