Quick Reference Guide
Storage Management Message Reference 135
2180 The
controller
battery Learn
cycle will start
in %1 days.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
The %1 indicates a
substitution variable.
The text for this
substitution variable is
displayed with the alert in
the Alert Log and can vary
depending on the
situation.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
2181 The
controller
battery Learn
cycle will start
in %1 hours.
OK / Normal /
Informational
Cause: The %1 indicates a
substitution variable.
The text for this
substitution variable is
displayed with the alert in
the Alert Log and can vary
depending on the
situation. This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
2182 An invalid
SAS config-
uration has
been
detected.
Critical /
Failure / Error
Cause: The controller and
attached enclosures are not
cabled correctly.
Action: See the hardware
documentation for
information on correct
cabling configurations.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2183 Replace
member
operation
failed on
physical
disk %1
Critical /
Failure / Error
Cause: The physical disk
being replaced has failed.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
2060.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information