Quick Reference Guide

134 Storage Management Message Reference
2178 The
controller
battery Learn
cycle has
timed out.
Warning /
Non-critical
Cause: The controller
battery must be fully
charged before the Learn
cycle can begin. The
battery may be unable to
maintain a full charge
causing the Learn cycle
to timeout. Additionally,
the battery must be able to
maintain cached data for a
specified period of time in
the event of a power loss.
For example, some
batteries maintain cached
data for 24 hours. If the
battery is unable to
maintain cached data for
the required period of
time, then the Learn cycle
will timeout.
Action: Replace the battery
pack as the battery is
unable to maintain a full
charge.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2179 The
controller
battery Learn
cycle has
been
postponed.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information