132 Storage Management Message Reference
2173 Un-supported
config-
uration
detected. The
SCSI rate of
the enclosure
man-agement
modules
(EMMs) is
not the same.
EMM0 %1
EMM1 %2.
Warning /
Non-critical
Cause: The EMMs in the
enclosure have a different
SCSI rate. This is an
unsupported configuration.
All EMMs in the enclosure
should have the same SCSI
rate. The % (percent sign)
indicates a substitution
variable. The text for this
substitution variable is
displayed with the alert in
the Alert Log and can vary
depending on the
situation.
Action: No action required.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2174 The
controller
battery has
been
removed.
Warning /
Non-critical
Cause: The controller
cannot communicate with
the battery, the battery may
be removed, or the contact
point between the
controller and the battery
may be burnt or corroded.
Action: Replace the battery
if it has been removed. If
the contact point between
the battery and the
controller is burnt or
corroded, you will need to
replace either the battery
or the controller, or both.
See the hardware
documentation for
information on how to
safely access, remove, and
replace the battery.
Clear Alert
Number:
None.
Related Alert
Number:
2188, 2318
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information