Quick Reference Guide
130 Storage Management Message Reference
2168 The non-
RAID SCSI
driver version
is older than
the minimum
required
level. See
readme.txt
for the
validated
driver version.
NOTE: Not
Applicable for
VMware ESXi
3.5 Update 4.
Warning /
Non-critical
Cause: The version of the
driver does not meet the
minimum requirements.
Storage Management may
not be able to display the
storage or perform storage
management functions
until you have updated the
system to meet the
minimum requirements.
Action: See the Readme
file for the validated driver
version. Update the system
to meet the minimum
requirements and then
reinstall Storage
Management.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2169 The
controller
battery needs
to be
replaced.
Critical /
Failure / Error
Cause: The controller
battery cannot recharge.
The battery may be old or
it may have been already
recharged the maximum
number of times.
In addition, the battery
charger may not be
working.
Action: Replace the battery
pack.
Clear Alert
Number:
None.
Related Alert
Number:
2118
2170 The
controller
battery charge
level is
normal.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information