Quick Reference Guide
Storage Management Message Reference 127
2162 Comm-
unication
regained
OK / Normal /
Informational
Cause: Communication
with an enclosure has been
restored. This alert is for
informational purposes.
Action: None
Clear Alert
Status: Alert
2162 is a clear
alert for alerts
2137 and
2292.
Related Alert
Number:
None.
2163 Rebuild
completed
with errors
Critical /
Failure / Error
Cause: You might be
attempting a RAID
configuration that is not
supported by the
controller..
Action: See the Storage
Management online help
for more information.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2164 See the
Readme file
for a list of
validated
controller
driver
versions
OK / Normal /
Informational
Cause: Storage
Management is unable to
determine whether the
system has the minimum
required versions of the
RAID controller drivers.
This alert is for
informational purposes.
Action: See the Readme
file for driver and firmware
requirements. In particular,
if Storage Management
experiences performance
problems, you should verify
that you have the
minimum supported
versions of the drivers and
firmware installed.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information