Quick Reference Guide

114 Storage Management Message Reference
2122
contd.
The controller status
displayed on the Health
subtab indicates whether
a controller has a failed or
degraded component.
See the enclosure
documentation for
information on replacing
enclosure components and
for other diagnostic
information.
2123 Redundancy
lost
Warning /
Non-critical
Cause: A virtual disk or an
enclosure has lost data
redundancy. In the case of
a virtual disk, one or more
physical disks included in
the virtual disk have failed.
Due to the failed physical
disk or disks, the virtual
disk is no longer
maintaining redundant
(mirrored or parity) data.
The failure of an additional
physical disk will result in
lost data. In the case of an
enclosure, more than one
enclosure component has
failed. For example, the
enclosure may have
suffered the loss of all fans
or all power supplies.
Action: Identify and
replace the failed
components. To identify the
failed component, select
the Storage object and
click the Health subtab.
Clear Alert
Number:
2124.
Related Alert
Number:
2048, 2049,
2057
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information