Quick Reference Guide
110 Storage Management Message Reference
2112 Enclosure was
shut down
Critical /
Failure / Error
Cause: The physical disk
enclosure is either hotter or
cooler than the maximum
or minimum allowable
temperature range.
Action: Check for factors
that may cause overheating
or excessive cooling. For
example, verify that the
enclosure fan is working.
You should also check the
thermostat settings and
examine whether the
enclosure is located near a
heat source. Make sure the
enclosure has enough
ventilation and that the
room temperature is not
too hot or too cold. See the
enclosure documentation
for more diagnostic
information.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2114 A consistency
check on a
virtual disk
has been
paused
(suspend-ed)
OK / Normal /
Informational
Cause: The check
consistency operation on
a virtual disk was paused
by a user.
Action: To resume the
check consistency
operation, right-click the
virtual disk in the tree view
and select Resume Check
Consistency.
Clear Alert
Number:
2115.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information