Quick Reference Guide
Storage Management Message Reference 109
2110 SMART
warning
degraded
Warning /
Non-critical
Cause: A disk is degraded
and has received a SMART
alert (predictive failure).
The disk is likely to fail in
the near future.
Action: Replace the disk
that has received the
SMART alert. If the
physical disk is a member
of a non-redundant virtual
disk, then back up the data
before replacing the disk.
CAUTION: Removing
a physical disk that
is included in a
non-redundant virtual
disk will cause the
virtual disk to fail and
may cause data loss.
Clear Alert
Number:
None.
Related Alert
Number:
None.
2111 Failure
prediction
threshold
exceeded due
to test
Warning /
Non-critical
Cause: A disk has
received a SMART alert
(predictive failure) due to
test conditions.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information