Quick Reference Guide

Storage Management Message Reference 107
2109 SMART
warning
temp-erature
Warning /
Non-critical
Cause: A disk has reached
an unacceptable
temperature and received a
SMART alert (predictive
failure). The disk is likely
to fail in the near future.
Action 1: Determine why
the physical disk has
reached an unacceptable
temperature. A variety of
factors can cause the
excessive temperature. For
example, a fan may have
failed, the thermostat may
be set too high, or the
room temperature may be
too hot or cold. Verify that
the fans in the server or
enclosure are working. If
the physical disk is in an
enclosure, you should
check the thermostat
settings and examine
whether the enclosure is
located near a heat source.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information