Quick Reference Guide

104 Storage Management Message Reference
2104 Controller
battery is
recond-
itioning
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
2105.
Related Alert
Number:
None.
2105 Controller
battery
recondition is
completed
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Status: Alert
2105 is a clear
alert for alert
2104.
Related Alert
Number:
None.
2106 Smart FPT
exceeded
Warning /
Non-critical
Cause: A disk on the
specified controller has
received a SMART alert
(predictive failure)
indicating that the disk is
likely to fail in the near
future.
Action: Replace the disk
that has received the
SMART alert. If the
physical disk is a member
of a non-redundant virtual
disk, then back up the data
before replacing the disk.
CAUTION: Removing
a physical disk that
is included in a
non-redundant virtual
disk will cause the
virtual disk to fail and
may cause data loss.
Clear Alert
Number:
None.
Related Alert
Number:
None.
Table 4-4. Storage Management Messages (continued)
Event ID Description Severity Cause and Action Related Alert
Information