2100 Temp-erature
exceeded the
maximum
warning
threshold
Warning /
Non-critical
Cause: The physical disk
enclosure is too hot.
A variety of factors can
cause the excessive
temperature. For example,
a fan may have failed,
the thermostat may be set
too high, or the room
temperature may be
too hot.
Action: Check for factors
that may cause
overheating. For example,
verify that the enclosure
fan is working. You should
also check the thermostat
settings and examine
whether the enclosure is
located near a heat source.
Make sure the enclosure
has enough ventilation and
that the room temperature
is not too hot. See the
physical disk enclosure
documentation for more
diagnostic information.
Clear Alert
Number:
2353.
Related Alert
Number:
2112
2101 Temp-erature
dropped
below the
minimum
warning
threshold
Warning /
Non-critical
Cause: The physical disk
enclosure is too cool.
Action: Check if the
thermostat setting is too
low and if the room
temperature is too cool.
Clear Alert
Number:
2353.
Related Alert
Number:
None.