User's Manual

Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Status: Alert 2091 is a clear alert for alert 2064.
Related Alert Number: None.
2092
Description: Physical disk rebuild completed
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Status: Alert 2092 is a clear alert for alert 2065.
Related Alert Number: None.
2094
Description: Predictive Failure reported.
Cause: The physical disk is predicted to fail. Many physical disks contain Self Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART
monitors the health of the disk based on indications such as the number of write operations that have been performed on the disk.
Action: Replace the physical disk. Even though the disk may not have failed yet, it is strongly recommended that you replace the disk.
If this disk is part of a redundant virtual disk, perform the Offline task on the disk; replace the disk; and then assign a hot spare and the rebuild will start
automatically.
If this disk is a hot spare, then unassign the hot spare; perform the Prepare to Remove task on the disk; replace the disk; and assign the new disk as a hot
spare.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
CAUTION: If this disk is part of a nonredundant disk, back up your data immediately. If the disk fails, you will not be able to recover the data.