User's Manual

Clear Alert Number: None.
Related Alert Number: None.
2075
Description: Copy of data completed on physical disk %2 from physical disk %1
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2060.
2076
Description: Virtual disk Check Consistency failed
Cause: A physical disk included in the virtual disk failed or an error exists in the parity information. A failed physical disk can cause errors in parity information.
Action: Replace the failed physical disk. You can identify which disk has failed by locating the disk that has a red X for its status. Rebuild the physical disk.
When finished, restart the check consistency operation.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2077
Description: Virtual disk format failed
Cause: A physical disk included in the virtual disk failed.
Action: Replace the failed physical disk. You can identify which physical disk has failed by locating the disk that has a red X for its status. Rebuild the physical
disk. When finished, restart the virtual disk format operation.