User's Manual

2350
Description: There was an unrecoverable disk media error during the rebuild.
Cause: The rebuild encountered an unrecoverable disk media error.
Action: Replace the disk.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2095, 2273
2351
Description: A physical disk is marked as missing.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: 2352. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: None.
2352
Description: A physical disk that was marked as missing has been replaced.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Status: Alert 2352 is a clear alert for alert 2351.
Related Alert Number: None.