User's Manual
Cause: The data on a source disk and the redundant data on a target disk is inconsistent.
Action: Restart the "Check Consistency" task. If you receive this alert again, review the alert messages for significant alerts related to the physical disks. If you
suspect that a physical disk has a problem, replace it and restore your data from backup.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2341, 2343
2343
Description: The Check Consistency logging of inconsistent parity data is disabled.
Cause: The Check Consistency can no longer report errors in the parity data.
Action: See the hardware documentation for more information.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2346
Description: Error occurred: %1
Cause: A physical device may have an error. The %1 indicates a substitution variable. The text for this substitution variable is generated by the firmware and
is displayed with the alert in the Alert Log. This text can vary depending on the situation.
Action: Verify the health of attached devices. Review the Alert Log for significant events. Run the PHY integrity diagnostic tests. You may need to replace faulty
hardware. Make sure the cables are attached securely. See "Cables Attached Correctly" for more information on checking the cables. See the hardware
documentation for more information.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2048, 2050, 2056, 2057, 2076, 2079, 2081, 2083, 2095, 2129, 2201, 2203, 2270, 2282, 2369
2347