User's Manual
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2337
Description: The controller is unable to recover cached data from the battery backup unit (BBU).
Cause: The controller was unable to recover data from the cache. This may occur when the system is without power for an extended period of time or when
the battery is discharged.
Action: Verify that the battery is charged and in good health. When the battery charge is unacceptably low, the battery cannot maintain cached data.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2338
Description: The controller has recovered cached data from the battery backup unit (BBU).
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2339
Description: The factory default settings have been restored.
Cause: This alert is provided for informational purposes.