User's Manual

2327
Description: The NVRAM is corrupt. The controller is reinitializing the NVRAM.
Cause: The nonvolatile random access memory (NVRAM) is corrupt. This may occur after a power surge, a battery failure, or for other reasons. The controller is
reinitializing the NVRAM. The controller properties will reset to the default settings after the reinitialization is complete.
Action: None. The controller is taking the required corrective action.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2266
2328
Description: The NVRAM is corrupt.
Cause: The nonvolatile random access memory (NVRAM) is corrupt.
Action: None. The controller is taking the required corrective action.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2329
Description: SAS port report: %1
Cause: The text for this alert is generated by the controller and can vary depending on the situation. The %1 indicates a substitution variable. The text for this
substitution variable is generated by the controller and is displayed with the alert in the Alert Log. This text can vary depending on the situation.
Action: Run the PHY integrity test diagnostics. Make sure the cables are attached securely. See "Cables Attached Correctly" for more information on checking
the cables. If the problem persists, contact technical support. See your system documentation for information about contacting technical support by using
telephone, fax, and Internet services.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.