User's Manual

Action: Reboot the system. If problem persists, make sure you have supported versions of the drivers and firmware. You may need to reinstall Storage
Management or Server Administrator.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2315
Description: Diagnostic message %1
Cause: This alert is provided for informational purposes. The %1 indicates a substitution variable. The text for this substitution variable is generated by the
utility that ran the diagnostics and is displayed with the alert in the Alert Log. This text can vary depending on the situation.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2316
Description: Diagnostic message %1
Cause: A diagnostics test failed. The %1 indicates a substitution variable. The text for this substitution variable is generated by the utility that ran the
diagnostics and is displayed with the alert in the Alert Log. This text can vary depending on the situation.
Action: See the documentation for the utility that ran the diagnostics for more information.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2318
Description: Problems with the controller battery or the controller battery charger have been detected. The battery health is poor.