User's Manual
Action: Upgrade to the same version of the firmware on both EMM modules.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2312
Description: A power supply in the enclosure has an AC failure.
Cause: The power supply has an AC failure.
Action: Replace the power supply.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: 2325. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: 2122, 2324.
2313
Description: A power supply in the enclosure has a DC failure.
Cause: The power supply has a DC failure.
Action: Replace the power supply.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: 2323. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: 2122, 2322.
2314
Description: The initialization sequence of SAS components failed during system startup. SAS management and monitoring is not possible.
Cause: Storage Management is unable to monitor or manage SAS devices.