User's Manual

Cause: The enclosure or an enclosure component is in a Failed or Degraded state.
Action: Verify the health of the enclosure and its components. Replace any hardware that is in a Failed state. See the hardware documentation for more
information.
Action: Verify the health of the enclosure and its components. Run diagnostics and check the LEDs to identify hardware that has failed or that is degraded.
Replace any hardware that is in a Failed state. See the hardware documentation for more information on replacing components and for additional
troubleshooting information.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2303
Description: The enclosure cannot support both SAS and SATA physical disks. Physical disks may be disabled.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2304
Description: An attempt to hot plug an enclosure management module (EMM) has been detected. This type of hot plug is not supported.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2211