User's Manual

Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: 2177. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: None.
2177
Description: The controller battery Learn cycle has completed.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Status: Alert 2177 is a clear alert for alert 2176.
Related Alert Number: None.
2178
Description: The controller battery Learn cycle has timed out.
Cause: The controller battery must be fully charged before the Learn cycle can begin. The battery may be unable to maintain a full charge causing the Learn
cycle to timeout. In addition, the battery must be able to maintain cached data for a specified period of time in the event of a power loss. For example, some
batteries maintain cached data for 24 hours. If the battery is unable to maintain cached data for the required period of time, then the Learn cycle will timeout.
Action: Replace the battery pack. The battery is unable to maintain a full charge.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2179
Description: The controller battery Learn cycle has been postponed.
Cause: This alert is provided for informational purposes.
Action: None.