User's Manual

2168
Description: The non-RAID SCSI driver version is older than the minimum required level. See readme.txt for the validated driver version.
Cause: The version of the driver does not meet the minimum requirements. Storage Management may not be able to display the storage or perform storage
management functions until you have updated the system to meet the minimum requirements.
Action: See the Readme file for the driver requirements. Update the system to meet the minimum requirements and then reinstall Storage Management.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
2169
Description: The controller battery needs to be replaced.
Cause: The controller battery cannot recharge. The battery may have been already recharged the maximum number of times. In addition, the battery charger
may not be working.
Action: Replace the battery pack.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2118
2170
Description: The controller battery charge level is normal.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.