Users Guide
Table 15-17. omconfig Physical Disk Commands
omconfig Blink Physical Disk
Does my controller support this feature? See "Supported Features."
You can blink the light (light emitting diode or LED display) on one or more physical disks attached to a controller. Use the following omconfig command syntax
to blink one or more physical disks.
Complete Syntax
omconfig storage pdisk action=blink controller=id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical disk. See "pdisk=<PDISKID> Parameter" for more information.
To obtain these values, you would enter omreport storage controller to display the controller IDs and then enter omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to blink physical disk 2 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To blink the physical disk described in this example, you would enter:
omconfig storage pdisk action=blink controller=1 pdisk=0:2
See "pdisk=<PDISKID> Parameter on SCSI, SATA, and ATA Controllers" and "Multiple Targets" for more information on physical disk specification. See "RAID
Controller Technology: SCSI, SATA, ATA, and SAS" to identify which technology a controller uses.
Required Command Levels
(1, 2, 3)
Optional name=value Pairs
Documentation Section
omconfig storage pdisk
action=blink controller=id pdisk=<PDISKID>
"omconfig Blink Physical Disk"
action=unblink controller=id pdisk=<PDISKID>
"omconfig Unblink Physical Disk"
action=remove controller=id pdisk=<PDISKID>
"omconfig Prepare to Remove Physical Disk"
action=initialize controller=id pdisk=<PDISKID>
"omconfig Initialize Physical Disk"
action=offline controller=id pdisk=<PDISKID>
"omconfig Offline Physical Disk"
action=online controller=id pdisk=<PDISKID>
"omconfig Online Physical Disk"
action=assignglobalhotspare controller=id pdisk=<PDISKID>
assign=<yes|no>
"omconfig Assign Global Hot Spare" and "omconfig
Unassign Global Hot Spare"
action=rebuild controller=id pdisk=<PDISKID>
"omconfig Rebuild Physical Disk"
action=cancelrebuild controller=id pdisk=<PDISKID>
"omconfig Cancel Rebuild Physical Disk"
action=removedeadsegments controller=id pdisk=<PDISKID>
"omconfig Remove Dead Segments"
action=clear controller=id pdisk=<PDISKID>
"omconfig Clear Physical Disk"
action=cancelclear controller=id pdisk=<PDISKID>
"omconfig Cancel Clear Physical Disk"
action=cancelreplacemember controller=id pdisk=<PDISKID>
"omconfig Cancel Replace Member"