Users Guide

omconfig storage controller action=enablealarm controller=id
where id is the controller ID as reported by the omreport storage controller command.
Example Syntax
For example, to enable the alarm on controller 1, you would enter:
omconfig storage controller action=enablealarm controller=1
omconfig Disable Controller Alarm
Does my controller support this feature? See "Supported Features."
Use the following omconfig command syntax to disable the controller alarm. See "Disable Alarm (Controller)" for more information.
Complete Syntax
omconfig storage controller action=disablealarm controller=id
where id is the controller ID as reported by the omreport storage controller command.
Example Syntax
For example, to disable the alarm on controller 1, you would enter:
omconfig storage controller action=disablealarm controller=1
omconfig Quiet Controller Alarm
Does my controller support this feature? See "Supported Features."
Use the following omconfig command syntax to quiet the controller alarm when it is sounding. See "Quiet Alarm (Controller)" for more information.
Complete Syntax
omconfig storage controller action=quietalarm controller=id
where id is the controller ID as reported by the omreport storage controller command.