Users Guide
omconfig Rescan Controller
Does my controller support this feature? See "Supported Features."
Use the following omconfig command syntax to rescan a controller. See "Rescan Controller" and "Rescan to Update Storage Configuration Changes" for more
information about using this command.
Complete Syntax
omconfig storage controller action=rescan controller= id
where id is the controller ID as reported by the omreport storage controller command.
Example Syntax
For example, to rescan controller 1, you would enter:
omconfig storage controller action=rescan controller= 1
omconfig Enable Controller Alarm
Does my controller support this feature? See "Supported Features."
Use the following omconfig command syntax to enable the controller alarm. See "Enable Alarm (Controller)" for more information.
Complete Syntax
Foreign
Configuration"
action=importrecoverforeignconfig controller=id
"omconfig
Import/Recover
Foreign
Configuration"
action=clearforeignconfig controller=id
"omconfig Clear
Foreign
Configuration"
action=setpatrolreadmode controller=id mode=manual|auto|disable
"omconfig Set Patrol
Read Mode"
action=startpatrolread controller=id
"omconfig Start
Patrol Read"
action=stoppatrolread controller=id
"omconfig Stop
Patrol Read"
action=setchangecontrollerproperties controller=<id> abortcheckconsistencyonerror=<enabled/disabled>
allowreplacemember=<enabled/disabled> loadbalance=<auto/disabled>
autoreplacememberonpredictivefailure=<enabled/disabled> bgirate=<rate> reconstructrate=<rate>
rebuildrate=<rate> checkconsistencyrate=<rate> redundantpathview=disabled
"omconfig Change
Controller Properties"
action=discardpreservedcache controller=id force=e|d
"omconfig Storage
Controller"
omconfig
storage vdisk
action=replacememberdisk controller=id vdisk=id source=<PDISKID> destination=<PDISKID>
"omconfig Storage
Virtual Disk"
NOTE: Rescan Controller is not supported on non-RAID SCSI or SAS controllers. You must reboot the system before Storage Management can see
configuration changes on non-RAID SCSI or SAS controllers.