Users Guide

Table 15-6.omreportConnectorCommands
omreport Enclosure Status
Table 15-7.omreportEnclosureCommands
omreport Temperature Probe Status
Table 15-8.omreportTemperatureProbeCommands
omreport Fan Status
Table 15-9.omreportFanCommands
Required Command Levels (1, 2, 3)
and name=value Pair
Use
omreport storage connector
controller=id
where id is the controller number. For
example: controller=0
Displays all connectors on the specified controller.
omreport storage connector
controller=id connector=id
where id is the controller number. For
example: controller=0
Displays information for the specified connector on the controller.
NOTE: When the connectors are connected to the enclosure in redundant path mode, the Name of the connector is
displayed as Logical Connector. See "Redundant Path Configuration" for more information.
Required
Command Levels
(1, 2, 3)
Optional name=value Pairs
Use
omreport
storage
enclosure
Displays property information for all enclosures attached to
the system.
controller=id enclosure=<ENCLOSUREID>
where id is the controller number and <ENCLOSUREID> is the enclosure
ID. Example for SCSI controllers: controller=0 enclosure=2. Example for
SAS controllers: controller=0 enclosure=1:2.
Displays the specified enclosure and its components. See
"enclosure=<ENCLOSUREID> Parameter" for more information
on specifying enclosures.
Required
Command
Levels (1, 2,
3)
Optional name=value Pairs
Use
omreport
storage
enclosure
Displays property information for all enclosures
attached to the system.
controller=id enclosure=<ENCLOSUREID> info=temps
where id is the controller number and <ENCLOSUREID> is the enclosure ID.
Example for SCSI controllers: controller=0 enclosure=2 info=temps. Example for
SAS controllers: controller=0 enclosure=1:2 info=temps.
Displays the temperature probes for the specified
enclosure. See "enclosure=<ENCLOSUREID>
Parameter" for more information on specifying
enclosures.
controller=id enclosure=<ENCLOSUREID> info=temps index=n
where id is the controller number and <ENCLOSUREID> is the enclosure ID and n
is the number of a temperature probe. Example for SCSI controllers: controller=0
enclosure=2 info=temps index=1. Example for SAS controllers: controller=0
enclosure=1:2 info=temps index=1.
Displays the specified temperature probe. See
"enclosure=<ENCLOSUREID> Parameter" for more
information on specifying enclosures.
Required
Command
Levels (1, 2, 3)
Optional name=value Pairs
Use
omreport
storage
enclosure
Displays property information for all enclosures
attached to the system.
controller=id enclosure=<ENCLOSUREID> info=fans
Displays the fans for the specified enclosure. See
"enclosure=<ENCLOSUREID> Parameter" for more