Users Guide
omreport Storage Help
Table 15-2.omreportStorageHelpCommands
omreport Controller Status
Table 15-3.omreportControllerCommands
omreport Global Information (Smart Thermal Shutdown Status)
Table 15-4.omreportGlobalInformationCommands
omreport Battery Status
Table 15-5.omreportBatteryCommands
omreport Connector Status
Required Command
Levels (1, 2, 3)
Use
omreport storage -?
Displays a list of storage components for which omreport commands are available.
omreport storage pdisk -?
Displays a list of the omreport storage pdisk parameters for displaying physical disk information. See "omreport Physical Disk
Status" for more information.
omreport storage vdisk -?
Displays a list of the omreport storage vdisk parameters for displaying virtual disk information. See "omreport Virtual Disk
Status" for more information.
omreport storage
controller -?
Displays a list of the omreport storage controller parameters for displaying controller information. See "omreport Controller
Status" for more information.
omreport storage
enclosure -?
Displays a list of the omreport storage enclosure parameters for displaying enclosure information. See "omreport Enclosure
Status" for more information.
omreport storage
connector -?
Displays a list of the omreport storage connector parameters for displaying connector information. See "omreport Connector
Status" for more information.
omreport storage battery
-?
Displays a list of the omreport storage battery parameters for displaying battery information. See "omreport Battery Status" for
more information.
omreport storage
globalinfo -?
Displays a list of the omreport storage globalinfo parameters for displaying global storage property information. See "omreport
Global Information (Smart Thermal Shutdown Status)" for more information.
Required Command Levels
(1, 2, 3)
Optional name=value Pairs
Use
omreport storage
controller
Displays property information for all controllers attached to the system.
controller=id
where id is the controller number. For
example: controller=0
Displays the specified controller and all attached components such as enclosures,
virtual disks, physical disks, and so on.
Required Command
Levels (1, 2, 3)
Optional
name=value Pairs
Use
omreport storage
globalinfo
Displays whether smart thermal shutdown is enabled or disabled. See "Channel Redundancy and Thermal
Shutdown" and "omconfig Global Enable Smart Thermal Shutdown" for more information.
Required Command Levels
(1, 2, 3)
Optional name=value Pairs
Use
omreport storage battery
Displays all batteries present on all controllers on the system. (Some
controllers do not have batteries.)
controller=id
where id is the controller number. For
example: controller=0
Displays the battery on the specified controller.