Users Guide

Does my controller support this feature? See "Supported Features."
Use the Cancel Check Consistency task to stop a check consistency operation that is in progress.
Pause Check Consistency
Does my controller support this feature? See "Supported Features."
Use the Pause Check Consistency task to pause a check consistency while it is in progress.
Resume Check Consistency
Does my controller support this feature? See "Supported Features."
Use the Resume Check Consistency task to resume a check consistency after it has been paused.
Blink and Unblink (Virtual Disk)
Does my controller support this feature? See "Supported Features."
The Blink and Unblink tasks blink or unblink the lights on the physical disks included in the virtual disk. See "Blink and Unblink (Virtual Disk)" for more
information.
Rename
Does my controller support this feature? See "Supported Features."
Use the Rename task to change the virtual disk's name. See "Virtual Disk Task: Rename" for more information.
Cancel Rebuild
NOTE: On the PERC 3/Si, 3/Di, and CERC SATA1.5/6ch controllers, reconfiguring a concatenated virtual disk to a RAID 1 may cause the virtual disk to be
in Resynching state. Performing a "Pause Check Consistency" or a "Cancel Check Consistency" on a virtual disk while it is in Resynching state will cause
the virtual disk to be in a Failed Redundancy state. See "Considerations for Concatenated to RAID 1 Reconfiguration on PERC 3/Si, 3/Di, and CERC
SATA1.5/6ch Controllers" for more information.
NOTE: The Pause Check Consistency task updates the virtual disk State property to Resynching Paused immediately. The Progress property may
continue to increment for up to three seconds. This time delay occurs because the polling task may take up to three seconds to query the task
information and update the display.
NOTE: On the PERC 3/Si, 3/Di, and CERC SATA1.5/6ch controllers, reconfiguring a concatenated virtual disk to a RAID 1 may cause the virtual disk to be
in Resynching state. Performing a "Pause Check Consistency" or a "Cancel Check Consistency" on a virtual disk while it is in Resynching state will cause
the virtual disk to be in a Failed Redundancy state. See "Considerations for Concatenated to RAID 1 Reconfiguration on PERC 3/Si, 3/Di, and CERC
SATA1.5/6ch Controllers" for more information.
NOTE: On the CERC SATA1.5/2s controller, you cannot change the default name of a concatenated virtual disk.
NOTE: Renaming a virtual disk generates alert "2159." On the PERC 3/Si, 3/Di, CERC SATA1.5/6ch, and CERC SATA1.5/2s controllers, alert "2159"
displays the new virtual disk name. On the PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4/IM, 4e/Si, 4e/Di, and CERC ATA100/4ch controllers, alert
"2159" displays the original virtual disk name.