Users Guide

Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 851. See "SNMP Support for Storage Management Alerts" for more information.
2356
Description: SAS SMP communications error %1.
Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the firmware and is displayed with the alert in the Alert
Log. This text can vary depending on the situation. The reference to SMP in this text refers to SAS Management Protocol.
Action: There may be a SAS topology error. See the hardware documentation for information on correct SAS topology configurations. There may be problems
with the cables such as a loose connection or an invalid cabling configuration. See "Cables Attached Correctly" for more information on checking the cables.
See the hardware documentation for information on correct cabling configurations. Verify that the firmware is a supported version.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2061
SNMP Trap Number: 754. See "SNMP Support for Storage Management Alerts" for more information.
2357
Description: SAS expander error: %1
Cause: The %1 indicates a substitution variable. The text for this substitution variable is generated by the firmware and is displayed with the alert in the Alert
Log. This text can vary depending on the situation.
Action: There may be a problem with the enclosure. Verify the health of the enclosure and its components. To verify the health of the enclosure, select the
enclosure object in the tree view. The Health subtab displays a red X or yellow exclamation point for enclosure components that are failed or degraded. See
the enclosure documentation for more information.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2061