Users Guide

Description: A bad disk block could not be reassigned during a write operation.
Cause: A write operation could not complete because the disk contains bad disk blocks that could not be reassigned. Data loss may have occurred on a
nonredundant virtual disk. Data redundancy may also be lost.
Action: Replace the disk.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2346
Local Response Agent (LRA) Alert Number: 2071
SNMP Trap Number: 904. See "SNMP Support for Storage Management Alerts" for more information.
2350
Description: There was an unrecoverable disk media error during the rebuild.
Cause: The rebuild encountered an unrecoverable disk media error.
Action: Replace the disk.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2095, 2273
Local Response Agent (LRA) Alert Number: 2071
SNMP Trap Number: 904. See "SNMP Support for Storage Management Alerts" for more information.
2351
Description: A physical disk is marked as missing.
Cause: This alert is provided for informational purposes.