Users Guide
Local Response Agent (LRA) Alert Number: 2070
SNMP Trap Number: 903. See "SNMP Support for Storage Management Alerts" for more information.
2347
Description: The rebuild failed due to errors on the source physical disk.
Cause: You are attempting to rebuild data that resides on a defective disk.
Action: Restore your data from backup. Review the Alert Log to see if you have received alert "2095." If you contact technical support, you may be asked for
the media and sense key errors reported by alert "2095." See your system documentation for information about contacting technical support by using
telephone, fax, and Internet services.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Alert Number: 2071
SNMP Trap Number: 904. See "SNMP Support for Storage Management Alerts" for more information.
2348
Description: The rebuild failed due to errors on the target physical disk.
Cause: You are attempting to rebuild data onto a disk that is defective.
Action: Replace the target disk. If a rebuild does not automatically start after replacing the disk, then initiate the Rebuild task. You may need to assign the new
disk as a hot spare in order to initiate the rebuild.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Alert Number: 2071
SNMP Trap Number: 904. See "SNMP Support for Storage Management Alerts" for more information.
2349