Users Guide

Cause: This alert is provided for informational purposes. The %1 indicates a substitution variable. The text for this substitution variable is generated by the
controller and is displayed with the alert in the Alert Log. This text can vary depending on the situation.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 751. See "SNMP Support for Storage Management Alerts" for more information.
2331
Description: A bad disk block has been reassigned.
Cause: The disk has a bad block. Data has been readdressed to another disk block. No data loss has occurred.
Action: Monitor the disk for other alerts or indications of poor health. For example, you may receive alert "2306." Replace the disk if you suspect there is a
problem.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 901. See "SNMP Support for Storage Management Alerts" for more information.
2332
Description: A controller hot plug has been detected.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.