Description: Single-bit ECC error. The controller DIMM is nonfunctional. There will be no further reporting.
Cause: The controller memory (the dual in-line memory module or DIMM) is malfunctioning. The DIMM must be replaced immediately. No further alerts will be
generated.
Action: Contact technical support to replace the controller memory. See your system documentation for information about contacting technical support by using
telephone, fax, and Internet services.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2061
SNMP Trap Number: 754. See "SNMP Support for Storage Management Alerts" for more information.
2322
Description: The DC power supply is switched off.
Cause: The power supply unit is switched off. Either a user switched off the power supply unit or it is defective.
Action: Check to see whether the power switch is turned off or on. If it is turned off, turn it on. If the problem is not corrected, verify that the power cord is
attached and functional. If the problem is still not corrected or if the power switch is already turned on, then replace the power supply unit.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: 2323. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2091
SNMP Trap Number: 1004. See "SNMP Support for Storage Management Alerts" for more information.
2323
Description: The power supply is switched on.
Cause: This alert is provided for informational purposes.