Users Guide
Cause: The power supply has a DC failure.
Action: Replace the power supply.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: 2323. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: 2122, 2322.
Local Response Agent (LRA) Alert Number: 2090
SNMP Trap Number: 1003. See "SNMP Support for Storage Management Alerts" for more information.
2314
Description: The initialization sequence of SAS components failed during system startup. SAS management and monitoring is not possible.
Cause: Storage Management is unable to monitor or manage SAS devices.
Action: Reboot the system. If problem persists, make sure you have supported versions of the drivers and firmware. You may need to reinstall Storage
Management or Server Administrator.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2051
SNMP Trap Number: 104. See "SNMP Support for Storage Management Alerts" for more information.
2315
Description: Diagnostic message %1
Cause: This alert is provided for informational purposes. The %1 indicates a substitution variable. The text for this substitution variable is generated by the
utility that ran the diagnostics and is displayed with the alert in the Alert Log. This text can vary depending on the situation.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.