Users Guide

Description: The firmware on the enclosure management modules (EMMs) is not the same version. EMM0 %1 EMM1 %2
Cause: The firmware on the EMM modules is not the same version. It is required that both modules have the same version of the firmware. This alert may be
caused when a user attempts to insert an EMM module that has a different firmware version than an existing module.
The %1 and %2 indicate a substitution variable. The text for these substitution variables is displayed with the alert in the Alert Log and can vary depending on
the situation.
Action: Upgrade to the same version of the firmware on both EMM modules.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2090
SNMP Trap Number: 853. See "SNMP Support for Storage Management Alerts" for more information.
2312
Description: A power supply in the enclosure has an AC failure.
Cause: The power supply has an AC failure.
Action: Replace the power supply.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: 2325. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: 2122, 2324.
Local Response Agent (LRA) Alert Number: 2090
SNMP Trap Number: 1003. See "SNMP Support for Storage Management Alerts" for more information.
2313
Description: A power supply in the enclosure has a DC failure.