Users Guide

Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 851. See "SNMP Support for Storage Management Alerts" for more information.
2304
Description: An attempt to hot plug an enclosure management module (EMM) has been detected. This type of hot plug is not supported.
Cause: This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2211
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 751. See "SNMP Support for Storage Management Alerts" for more information.
2305
Description: The physical disk is too small to be used for a rebuild.
Cause: The physical disk is too small to rebuild the data.
Action: Remove the physical disk and insert a new physical disk that is the same size or larger than the disk that is being rebuilt. The new physical disk must
also use the same technology (for example, SAS or SATA) as the disk being rebuilt. If the rebuild does not start automatically after you have inserted a
suitable physical disk, then run the "Rebuild" task. See "Replacing a Failed Disk" for more information.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.