Users Guide
2292
Description: Communication with the enclosure has been lost.
Cause: The controller has lost communication with an enclosure management module (EMM). The cables may be loose or defective.
Action: Make sure the cables are attached securely. See "Cables Attached Correctly" for more information on checking the cables. Reboot the system.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: 2162. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2091
SNMP Trap Number: 854. See "SNMP Support for Storage Management Alerts" for more information.
2293
Description: The enclosure management module (EMM) has failed.
Cause: An enclosure management module (EMM) has failed. The failure may be caused by a loss of power to the EMM. The EMM self test may also have
identified a failure. There could also be a firmware problem or a multi-bit error.
Action: Replace the EMM. See the hardware documentation for information on replacing the EMM.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2091
SNMP Trap Number: 854. See "SNMP Support for Storage Management Alerts" for more information.
2294
Description: A device has been inserted.
Cause: This alert is provided for informational purposes.