Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 1151. See "SNMP Support for Storage Management Alerts" for more information.
2190
Description: The controller has detected a hot-plugged enclosure.
Cause: This alert is provided for informational purposes. The SAS controller with firmware version 6.1 or later has detected a hot-plugged enclosure.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None
SNMP Trap Number: 751. See "SNMP Support for Storage Management Alerts" for more information.
2191
Description: There are too many enclosures attached to the controller. This is an unsupported configuration.
Cause: There are too many enclosures attached to the controller port. When the enclosure limit is exceeded, the controller loses contact with all enclosures
attached to the port.
Action: Remove the excessive enclosures. You must remove the enclosures that have been added last and that are causing the enclosure limit to be
exceeded. Refer to the hardware documentation for valid configurations.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2211
Local Response Agent (LRA) Alert Number: 2091