Users Guide

2185
Description: Replace member operation stopped for rebuild of hot spare on physical disk
Cause: This alert is provided for informational purposes.
Action: None.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: 2060.
Local Response Agent (LRA) Alert Number: None
SNMP Trap Number: 903. See "SNMP Support for Storage Management Alerts" for more information.
2186
Description: The controller cache has been discarded.
Cause: The controller has flushed the cache and any data in the cache has been lost.This may occur when the system has memory or battery problems.
Although user data may have been lost, this alert does not always indicate that relevant or user data has been lost.
Action: Verify that the battery and memory are functioning properly.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2060
SNMP Trap Number: 753. See "SNMP Support for Storage Management Alerts" for more information.
2187
Description: Single-bit ECC error limit exceeded on the controller DIMM.
Cause: The controller memory (the dual in-line memory module or DIMM) is malfunctioning.