Users Guide

Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Status: Alert 2162 is a clear alert for alerts 2137 and 2292.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 851. See "SNMP Support for Storage Management Alerts" for more information.
2163
Description: Rebuild completed with errors
Cause: See "A Rebuild Completes with Errors" for more information.
Action: See "A Rebuild Completes with Errors" for more information.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2071
SNMP Trap Number: 904. See "SNMP Support for Storage Management Alerts" for more information.
2164
Description: See readme.txt for a list of validated controller driver versions.
Cause: This alert is generated for informational purposes. Storage Management is unable to determine whether the system has the minimum required
versions of the RAID controller drivers.
Action: See the Readme file for driver and firmware requirements. In particular, if Storage Management experiences performance problems, you should verify
that you have the minimum supported versions of the drivers and firmware installed.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.